Pallet Stone Oiling
Apply micro-droplets of Moebius 9415 every third tooth on the impulse plane and inspect under 20× stereo magnification for even film spread.
Workshop Procedures
Consistent epilame treatment on escape-wheel teeth prevents oil migration across multi-year service intervals.
Apply micro-droplets of Moebius 9415 every third tooth on the impulse plane and inspect under 20× stereo magnification for even film spread.
Verify beat error below 0.2 ms across dial-up and crown-down orientations before performing fine hairspring centering at the stud.